Full automatic dispensing machine is a necessary product for automatic production in China at this stage, but many penyou who have touched the automatic dispensing machine are likely to find that the internal structure of the full-automatic dispensing machine is actually very complex. It is composed of mobile phone software and hardware configuration. Therefore, many problems are inevitable in the whole process of applying the full-automatic dispensing machine, If a problem occurs, we must find a way to deal with it as soon as possible, but how should we actually solve it?

① Up glue
First, it is necessary to determine whether the gray black pipe is applied. Do not immediately add UV strong glue to the working pressure cylinder. First discharge the original UV strong glue, and then pour the UV glue into the empty working pressure cylinder again. Generally speaking, the UV glue in the working pressure cylinder will cause bubbles after a period of time, which will lead to unstable glue output.
② Needle tube
Generally speaking, all needles below No. 20 are likely to cause gas problems, that is, leakage or vertical flow. In case of such conditions, small, general metal or conical side needles should be used as far as possible to prevent the use of winding or Teflon needles s.

③ The water flow of automatic dispensing machine is very slow
If you encounter the problem of slow water flow, you should change the pipeline from 1 / 4 to 3 / 8. If the pipeline is not necessary, the less the better. In addition to changing the pipeline, you also need to change the rubber outlet and standard air pressure, so that you can accelerate the water flow.
④ If the bubble in the liquid is too large and the valve opening time is too short, it will be possible to bring the gas into the liquid. In case of such a situation, we should reduce the working pressure of the liquid and use a conical needle.
⑤ Cleaning of epoxy resin adhesive
If you can, each shift uses the storage working pressure cylinder of general xylene organic solvent to clean automatically, and the cleaning effect is often very good.
Automatic dispensing machine, semi-automatic dispensing machine

⑥ Valve leakage of automatic dispensing machine
This kind of problem is generally found that after the oil distributor is shut down, generally speaking, this kind of situation is caused by the small specification of the applied needle. Too small needle tube will affect the fluidity of liquid and lead to back pressure. As a result, the problem of leakage will occur soon after the oil circuit distributor is closed. In fact, too small needle tube will also endanger the exhaust bubble position when the oil circuit distributor is gradually applied. This kind of problem can be solved by replacing a large needle tube. The back pressure caused by conical side needle tube is at least, and the liquid fluidity is the most smooth.

⑦ The size of automatic dispensing machine is different
In case of inconsistency, it is generally caused by the instability of the working pressure cylinder storing liquid or the working pressure of gas. The working pressure transformer at the air inlet shall be set at 10-15psi lower than the minimum working pressure in the plant. The working pressure applied by the working pressure cylinder shall be at the working pressure above the middle of the transformer, and the applied working pressure shall be prevented from being at the low working pressure part of the barometer. The operating pressure of oil circuit Distributor shall be at least above 60psi to ensure stable glue delivery. Finally, check the glue out time. If it is lower than 15 / 1000 seconds, the glue out will be unstable. The dispensing time will become more and more stable.
⑧ The quick drying adhesive is blocked on the connector of oil circuit distributor and its pipeline
In fact, generally speaking, the key to this kind of situation is that there is too much moisture in the body or the quick drying glue that has been reused for many times. It should be ensured to apply fresh quick drying glue, and then completely clean the aceton toluene with moisture in the body at the end of the pipeline, The applied gas shall be clearly dry, and the filter device shall be refitted between the air compressor and oil circuit distributor system in the plant (N2 shall be applied if the above method still fails).